Engineer inspecting the deposit-plugged tube sheet of a compressor cooler at a Gulf Coast petrochemical plant
CASE STUDY · PETROCHEMICAL · COMPRESSOR COOLERS

Every report said in control, and mild steel corrosion was under 0.1 mpy. Three compressor coolers were failing anyway.

~$2.5M/yr recovered · 6 cleanings and 3 shutdowns a year eliminated
~$2.5M/yr
Value recovered a year
6 → 0
Online cleanings a year
3 → 0
Unit shutdowns a year
<0.1 mpy
Mild steel corrosion held

What this case study covers

A Gulf Coast petrochemical plant ran a neutral-pH phosphate program with mild steel corrosion under 0.1 mpy and every routine parameter in range. Three compressor coolers still fouled, forcing 6 online cleanings and 3 short unit shutdowns a year. The lab called the deposit calcium phosphate. An independent review found what the lab method couldn’t show.

Inside this case study

← Back to Petrochemical Compressor Cooler Case Study
📄

Download the Full Case Study

Free · PDF · No spam

✅

Your download is ready

Thank you. Click the button below to download the full case study PDF.

Download PDF

Jim may also be in touch — feel free to reply directly with any questions.

🔒 No spam · Independent advisory · No chemistry sold

Independent · Vendor-Neutral

Have a similar challenge at your facility?

Most assessments begin with a remote review. No vendor pitch — just engineering.

Schedule a Discovery Call